class:: Peak summary:: Track peak signal amplitude. related:: Classes/PeakFollower categories:: UGens>Analysis>Amplitude Description:: Outputs the peak amplitude of the signal received at the input. When a trigger occurs at the code::reset:: input, the maximum output value is reset to the current value. Internally, the absolute value of the signal is used, to prevent underreporting the peak value if there is a negative DC offset. To obtain the minimum and maximum values of the signal as is, use the link::Classes/RunningMin:: and link::Classes/RunningMax:: UGens. classmethods:: method::ar, kr argument::in The input signal. argument::trig Trigger. Resets the output value to the current input value. A trigger happens when the signal changes from non-positive to positive. Examples:: code:: ( { SinOsc.ar( Peak.ar(Dust.ar(20), Impulse.ar(0.4)) * 500 + 200, 0, 0.2 ) }.play; ) // follow a sine lfo, reset rate controlled by mouse x ( { SinOsc.ar( Peak.kr(SinOsc.kr(0.2), Impulse.kr(MouseX.kr(0.01, 2, 1))) * 500 + 200, 0, 0.2 ) }.play; ) ::