class:: LeakDC
|
||
|
summary:: Remove DC
|
||
|
related:: Classes/DC
|
||
|
categories:: UGens>Filters>Linear
|
||
|
|
||
|
|
||
|
Description::
|
||
|
|
||
|
This is a linear filter that removes DC bias from a signal. Specifically, this is a one-pole highpass filter implementing the formula code:: y[n] = x[n] - x[n-1] + coef * y[n-1] ::. The frequency response of this filter is dependent on the sample rate of the server and the calculation rate of the UGen.
|
||
|
|
||
|
classmethods::
|
||
|
|
||
|
method::ar, kr
|
||
|
|
||
|
argument::in
|
||
|
|
||
|
The input signal.
|
||
|
|
||
|
|
||
|
argument::coef
|
||
|
|
||
|
Leak coefficient.
|
||
|
|
||
|
|
||
|
argument::mul
|
||
|
|
||
|
Output will be multiplied by this value.
|
||
|
|
||
|
|
||
|
argument::add
|
||
|
|
||
|
This value will be added to the output.
|
||
|
|
||
|
|
||
|
Examples::
|
||
|
|
||
|
code::
|
||
|
(
|
||
|
{
|
||
|
var a;
|
||
|
a = LFPulse.ar(800, 0.5, 0.5, 0.5);
|
||
|
[a, LeakDC.ar(a, 0.995)]
|
||
|